Section title: Requests for Interpretation
RFI #
1651
270 same subsriber
Description

Is it compliant with the TR3 to send two 2000C loops for the same subscriber for one information receiver (loop 2000B)?

Information Source (Loop 2000A)
Information Receiver (Loop 2000B)
Subscriber (Loop 2000C)
Eligibility or Benefit Inquiry
Subscriber (Loop 2000C) - same as above
Eligibility or Benefit Inquiry

Followup Information received from the submitter - This is a batch environment which allows for multiple patients inquiries/requests per transaction in general.

RFI Response

Yes, it is compliant with the 005010X279A1 TR3 to send two 2000C loops for the same subscriber for one information receiver (loop 2000B) in both the 270 and 271 when the transaction is used in a batch environment.

DOCUMENT ID
005010X279